Measuring the pressure-flow characteristics of a proportional pilot operated pressure relief valve

Authors

DOI:

https://doi.org/10.35925/j.multi.2023.2.1

Keywords:

amplifier card, hydraulic pressure relief valve, static characteristics

Abstract

The investigation of a pilot operated proportional pressure relief valve is described in this article. Different measurements are performed with a hydraulic test bench under laboratory conditions. A VT-VSPA1-1 amplifier module is used to control the current of the valve’s solenoid. The characteristics of the valve are determined as a function of the pressure – command value of the amplifier – volume flow rate. The results of the measurements can provide input data for the refinement of the mathematical model of the unit, which will be set up in the future.

Downloads

Published

2023-12-15