Measuring the pressure-flow characteristics of a proportional pilot operated pressure relief valve
DOI:
https://doi.org/10.35925/j.multi.2023.2.1Keywords:
amplifier card, hydraulic pressure relief valve, static characteristicsAbstract
The investigation of a pilot operated proportional pressure relief valve is described in this article. Different measurements are performed with a hydraulic test bench under laboratory conditions. A VT-VSPA1-1 amplifier module is used to control the current of the valve’s solenoid. The characteristics of the valve are determined as a function of the pressure – command value of the amplifier – volume flow rate. The results of the measurements can provide input data for the refinement of the mathematical model of the unit, which will be set up in the future.